Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Diesel Generator Sets

3516B (50 Hz) Generator Set

  • Minimum Rating
    2000 kVA
  • Maximum Rating
    2500 kVA
  • Emissions
    Low Fuel, Low Emissions
  • Voltage
    380 to 11000 Volts
Generator Set Specifications
Minimum Rating
2000 kVA
Maximum Rating
2500 kVA
Emissions
Low Fuel, Low Emissions
Voltage
380 to 11000 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Engine Specifications
Engine Model
3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69 in
Stroke
8.46 in
Stroke
Displacement
4764.73 in
Displacement
4764.73 in³
Compression Ratio
15.5:1
Aspiration
TA
Fuel System
Electronic unit injection
Governor Type
Adem™3
Displacement
4210.64 in³
Stroke
7.48 in
Generator Set Dimensions
Length
233.4 in
Length
251.7 in
Width
90 in
Height
93.2 in
Dry Weight
31900 lb
Dry Weight
40320 lb
  • Air Inlet
    • Air cleaner
  • Cooling
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Fuel
    • Secondary fuel filter
    • Fuel priming pump
    • Primary fuel filter with integral water separator
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
  • Power Termination
    • Busbar
  • Control Panel
    • EMCP 4.2B
  • General
    • Paint - Caterpillar Yellow except rails and radiators gloss black
  • Exhaust
    • Exhaust mufflers (except Tier 4)
  • Generator
    • Permanent magnet excitation (PMG)
    • Internal excitation (IE)
    • Anti-condensation heater
    • Oversize and premium generators
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Control Panels
    • Generator temperature monitoring & protection
    • Digital I/O module
    • Load share module
    • EMCP 4.3, EMCP 4.4
    • Remote monitoring software
  • Mounting
    • Spring-type vibration isolator
    • IBC isolators
    • Rubber anti-vibration mounts
  • Starting/Charging
    • Oversize batteries
    • Charging alternator
    • Heavy-duty starting system
    • Jacket water heater
    • Air starting motor with control and silencer
    • Battery chargers
  • General
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • EU Certificate of Conformance (CE)
    • The following options are based on regional and product configuration:
    • Enclosures: sound attenuated, weather protective
    • Automatic transfer switches (ATS)
    • UL 2200 package
    • Integral & sub-base UL listed dual wall fuel tanks
    • Integral & sub-base fuel tanks
    • EEC Declaration of Conformity
    • CSA Certification