Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Diesel Generator Sets

C175-20

  • Minimum Rating
    3150 kVA
  • Maximum Rating
    4000 kVA
  • Emissions
    Low Fuel, Low Emissions
  • Voltage
    3300 to 11000 Volts
Generator Set Specifications
Minimum Rating
3150 kVA
Maximum Rating
4000 kVA
Emissions
Low Fuel, Low Emissions
Voltage
3300 to 11000 Volts
Frequency
50 Hz
Speed
1500 RPM
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Engine Specifications
Engine Model
C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Bore
6.89 in
Stroke
8.66 in
Displacement
6456.31 in³
Compression Ratio
15:03:01
Aspiration
Turbo Aftercooled
Fuel System
Common Rail
Governor Type
ADEM™ A4
Aspiration
Turbo Aftercooled
Fuel System
Common Rail
Bore
6.89 in
Displacement
6456.31 in³
Stroke
8.66 in
Generator Set Dimensions
Length
261.5 in
Length
330.6 in
Width
85.4 in
Width
330.6 in
Height
87.6 in
Height
150.7 in
Dry Weight
55100 lb
Dry Weight
66200 lb
  • Air Inlet
    • 4 x Single element canister air cleaners with service indicator(s).
  • Control Panel
    • Engine cycle crank
    • Oil pressure (psi, kPa or bar)
    • Digital Indicators
    • Coolant temperature
    • Environmental sealed front face
    • Frequency (Hz)
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Text alarm / event descriptions
    • Low coolant level
    • Volts (L-L & L-N)
    • Auto / start / stop control
    • Warning / shutdown indicators
    • Emergency stop pushbutton
    • Engine cool-down timer
    • DC volts
    • High coolant temperature
    • Operating hours
    • Low oil pressure
    • EMCP 4.2B
    • Amps (per phase & average)
    • 4 Programmable relay Inputs
    • Alarm acknowledge
    • 4 Programmable relay output
    • Failure to start (overcrank)
    • Overspeed
    • Lamp test
    • 24 Volt DC operation
    • Wall mounted controls
    • RPM
  • Cooling System
    • SCAC cooling
    • Coolant sensors
    • JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
    • AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI
  • Exhaust
    • Dry exhaust manifold
    • Bolted flange (ANSI 6" & DIN 150) with bellow for each turbo (Qty 4). 50 Hz
  • Fuel
    • Filters x 3
    • Secondary / tertiary fuel filters
    • 4 Micron spin on type
    • 10 Micron spin on type
    • Engine mounted filters x 3
    • Primary fuel filter water / fuel water separator
  • Generators and Attachments
    • Salient Pole
    • RFI suppression
    • Anti condensation space Heater
    • IEC Platinum Stator RTDs
    • Form wound
    • NEMA Class H insulation
    • Voltage regulator:
    • Reactive droop capability
    • Min/max Exciter limiter
    • 3 Phase voltage sensing
    • Exciter diode monitor
    • 6 Leads
    • 3 Phase brushless
    • Right side extension box, bottom cable entry
    • Permanent magnet
    • Class H temperature rise at 40C ambient
  • Governing System
    • ADEM A4
    • Redundant Shutdown (Overspeed protection through a duplicate speed sensing system)
  • Lube System
    • Oil drain lines and valve
    • Gear type lube oil pump
    • Oil filter, filler and dipstick
    • Integral lube oil cooler
    • Lubricating oil
    • Fumes disposal
  • Mounting Systems
    • Rails - Engine / Generator
    • Rubber anti-vibration mounts (shipped loose)
  • Starting / Charging System
    • Batteries and battery rack w/cables
    • Dual 24 volt electric starting motors
    • Battery disconnect switch
  • General
    • SAE standard rotation
    • Right hand service
    • Paint - Caterpillar Yellow with high gloss black rails
  • Air Inlet Systems
    • Single element air cleaner
  • Control Panels
    • EMCP 4.3 and EMCP 4.4
    • EMCP and MV and HV power connection locations
    • Load share module
    • EMCP voltage and current sensing groups
    • Speed adjust
    • Annunciator modules
    • Customer interface options
    • Generator temperature monitoring
    • E-Stop
    • Interconnect harness
    • Generator harness
    • Modbus monitoring of packages
    • Vandal proof panel door
  • Cooling System
    • Package mounted radiators
    • Remote radiators
    • Fuel cooler
  • Crankcase Systems
    • Explosive relief valves
    • Crankcase ventilation system
  • Exhaust System
    • Front housing - Standby or mission critical
    • Front housing - Prime or continuous
    • Exhaust collectors / Manifold
    • Mufflers (15, 25 and 34 dBA)
  • Fuel System
    • Primary fuel filter
  • Generators and Attachments
    • Medium voltage - 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
    • Thermostat for space heater
    • Generator air cleaner
    • Differential current transformers - (5, 9 and 15 kV Class)
  • Instrumentation
    • Pyrometer and thermocouples
  • Lube System
    • Lube oil heater
    • Lube oil heater with crankcase explosion relief valve
    • Drain group oil pans
    • Lubricating oil
    • Electric prelube pumps
    • Oil filters
  • Mounting System
    • Rubber anti-vibration mounts
    • Spring type linear vibration isolators
    • IBC vibration isolators - Shipped loose
  • Special Tests / Reports
    • Generator test report
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard genset TVA (Torsional Vibration Analysis) report
    • Custom genset TVA report
    • Special test charge - Engine only
    • Genset fuel consumption test
    • Standard engine test charge
  • Starting / Charging System
    • 24 Volt electric starting motors
    • Air starting motor
    • Air pressure regulator
    • Starter location covers
    • 24 Volt battery sets - Dry
    • 20, 35 and 50 Amp battery chargers
    • Charging alternators - Dry
    • Jacket water heaters
  • General
    • Special paint - 3500, Colors (other than Caterpillar yellow) or high performance paints
    • US aid emblem
    • Service tools
    • Engine barring group
    • Manual
    • Engine barring air powered
    • control GP - Air powered bar group