Electric Power
DG275-2 (3 phase)
-
Voltage120 / 208, 120 / 240, 277 / 480, 346 / 600 VAC
-
Engine Model14.2 L Spark - Ignited
-
Fuel TypeNatural Gas
-
Frequency60 Hz
Generator Set Specifications
- Voltage
- 120 / 208, 120 / 240, 277 / 480, 346 / 600 VAC
- Frequency
- 60 Hz
- Natural Gas Rating
- 275 eKW
- Emissions
- U.S. EPA Certified for Non-Emergency Application
- Speed
- 1800 rpm
- Displacement
- 864.71 in³
Engine Specifications
- Engine Model
- 14.2 L Spark - Ignited
- Fuel Type
- Natural Gas
- Fuel System
- Carburetor, Down Draft
- Compression Ratio
- 9.5:1
- Bore
- 5.31 in
- Stroke
- 6.5 in
Generator Set Dimensions
- Length
- 136 in
- Width
- 57.6 in
- Height
- 66.1 in
- Weight
- 6274 lb
-
Cooling
- Factory-installed radiator
- 50/50 Ethylene glycol antifreeze
- Closed coolant recovery system
- Standard ambient temperatures up to 50°C (122°F)
- Radiator and cooling fan complete with protective guards
-
Air Inlet
- Single element air filter
-
Fuel
- Primary and secondary fuel shut-off
- Low fuel pressure switch
- Fuel pressure test po
- Dual lock off valves
- NPT connection
- Natural Gas or LP Vapor
-
Generator
- Class H insulation material
- Permanent magnet excitation
- Full load capacity alternator
- Permanent magnet excitation
- Integrated Voltage Regulator
- Class H insulation material
- Full load capacity alternator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
-
Exhaust
- Exhaust outlet with 3” pipe
-
Controls
- EMCP 4.2 Series generator set controller
-
Mounting
- Vibration isolaton (puck type)
- Rubber vibration isolators
-
Electric Starting and/or Prelube
- Solenoid activated starter motor
- Engine electrical system
- Battery cables
- Solenoid activated starter motor
-
Electric Power - Package Serial Number Prefix
- Battery charging alternator
-
Governor
- Electronic governor (non adjustable)
-
Control Panel
- EMCP 4.2 Series generator set controller
-
Starting/Charging
- Batteries with rack and cables
- 12 volt starting motor
-
Starting/Charging
- Charging alternator
- Jacket water heater
- Battery heater
- Battery charger – UL Listed 10 amp
-
General
- Suitable for Use as Service Equipment (SUSE)
- CSA Certification
- Enclosures: sound attenuated, weather protective
- Automatic transfer switches (ATS)
- UL 2200 package
-
Generator
- Anti-condensation heater
- Shunt trip and auxiliary contact breaker
- Thermal magnetic or electronic trip MCCBs
- Excitation: [ ] Permanent Magnet Excited (PM)
- Anti-condensation heater
- Oversize and premium generators