Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Offshore Generator Sets

8CM25C

  • Minimum Rating
    3200 kV·A
  • Maximum Rating
    3200 kV·A
  • Emissions
    IMO Tier II
  • Aspiration
    Turbocharged-Aftercooled
Engine Specifications
Minimum Rating
3200 kV·A
Maximum Rating
3200 kV·A
Emissions
IMO Tier II
Aspiration
Turbocharged-Aftercooled
Stroke
15.7 in
Bore
10.0 in
Displacement
9959.0 in3
Engine Control
Electronic
Generator Set Control
Electronic
Weight
116845 lb
Aspiration
Turbocharged-Aftercooled
Bore
10 in
Displacement
9959 in³
Stroke
15.7 in
Dimensions
Length
359.4 in
Height
174.7 in
Width
99.8 in
Height
174.7 in
Length
359.4 in
Width
99.8 in
Capacity for Liquids
Cooling System
165.0 gal
Lube Oil System
645.0 gal
  • Engine Indicators
    • Gauge board with set liquid damped pressure gauges for: fuel, lubricating oil, fresh water, starting air, and charge air.
    • On-engine thermometers for fuel, lubricating oil, fresh water, and charge air
    • Electric remote speed indicator
    • Turbocharger and remote speed indicator
    • Exhaust gas temperature indicator
  • Engine
    • Motor-driven barring gear, fitted on engine
    • Reversing contractor and pushbutton switch with cable
    • Electronic speed setting equipment with actuator and speed pick-up
    • Emergency shutdown equipment with pushbutton, separate, for manual emergency stop
  • Control
    • Manual control on engine, including: control panel with start /stop key, speed setting device, mechanical shutdown device, change over of control functions from engine to remote control
    • Starting solenoid valve on engine, 24 V DC
    • Separate electronic speed governor
  • Monitoring for Unattended Operation
    • Pressure switches, mounted on engine, for: - Lube oil pressure at full load below danger level - Low lube oil pressure - Lube oil pressure below danger level - Lube oil pressure prelubrication failed - Low fresh water pressure at engine inlet - Fresh water pressure at engine inlet below danger level - Low fresh water pressure in LT circuit - Low starting air pressure - Low control air pressure engine/shutdown air pressure - Low fuel pressure at engine inlet Switches for: - High lube oil temperature at engine inlet - Lube oil temperature at engine inlet above danger level - High water temperature at engine inlet - Water temperature at engine outlet above danger level - High charge-air temperature at engine inlet - Detection of water in charge-air duct - Leak fuel level - Alarm contact for high differential pressure at fuel filter - Alarm contact for high differential pressure at lube oil back flushing filter - Set of thermocouples after each cylinder, before and after turbocharger - Crankcase oil mist detector Control Cabinet with housings for wall mounting, including: - Protection equipment designed for automatic and manual stop input signals, starting interlock input signals, monitoring for the wire break of the input signal units and the emergency shutdown solenoid - Speed recording system for overspeed, firing speed and minimum speed - Start /stop logic, controlled by engine automatic start (optional) - Service hour counter - Noris alarm system, cassette type, designed for alarm inputs for the engine including exhaust mean-value monitoring equipment as well as alarm inputs for the propulsion plant - Group alarm panel for the bridge and with optional and acoustical alarm equipment
  • Starting Air System
    • Separate non-return valve for the starting air pipe to the engine
  • Air Intake System
    • Air intake filter, fitted on the turbocharger
    • Air bottles, separate
  • Diesel Oil System
    • Separate circulating pump driven by electric motor, horizontal or vertical
    • Duplex filter with differential pressure indication
  • Exhaust System
    • Turbocharger at free end with transition nozzle (0 degrees from the vertical and away from engine), with compressor cleaning device
    • Expansion joint separate
    • Separate silencer and spark arrester, unlagged 35 dB(A)
  • Fresh Cooling Water System
    • HT pump, fitted on engine
    • LT pump, separate, vertical design, electric motor driven
    • HT thermostat, not powered and separate
    • Engine preheating equipment, fitted on base frame
  • Lubricating Oil System
    • Plate cooler, fitted on engine
    • Force pump, fitted on engine
    • Prelubrication pump, fitted on base frame, electric motor driven
    • Boll and Kirch automatic backflushing filter, separate
    • Duplex filter with differential pressure indication, separate
    • Pressure control valve, separate
    • Thermostat, not powered, separate
  • Connecting Parts- Engine
    • Set of connecting parts between flange coupling and flywheel
    • Flexible flange coupling between engine and generator
    • Base frame with flywheel guard and incorporating lube oil sump tank, for engine and generator
    • Mounting of engine and generator on the base frame
    • Set of bonded rubber rails for resilient mounting of the base frame
    • Set of flexible pipe connections
  • Tools
    • Set of tools for the engine including hydraulic tightening tools and nozzle tester
    • Set of tools for turbocharger
    • Inside micrometer for cylinder liners
    • Ruler for cylinder liner
  • Spare Parts
    • Set of engine spare parts for unrestricted operation
    • Set of spare flexible pipe connections