3512B (50 Hz) Generator Set

Exterior View

3512B (50 Hz) Generator Set

Standby Rating1625/1600/1500 kVA
Prime Power Rating1500/1360 kVA
Emissions/Fuel StrategyLow Fuel, Low Emissions
Voltage380 to 415 Volts
product-tabs-bg

Learn more about our 3512B (50 Hz) Generator Set

Caterpillar is leading the power generation market with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Standby Rating
1625/1600/1500 kVA
Prime Power Rating
1500/1360 kVA
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Mission Critical, Prime
Maximum Rating
1625 kVA
Minimum Rating
1320 kVA
Engine Model
3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
6.69in
Stroke
7.48in
Displacement
3161.03in³
Compression Ratio
14.0:1
Aspiration
TA
Fuel System
Electronic Unit Injection
Governor Type
™ A3" data-metric=""> ADEM A3
Length - Minimum
216in
Length - Maximum
216.1in
Width - Minimum
90in
Width - Maximum
90in
Height - Minimum
95.3in
Height - Maximum
95.3in
Dry Weight - Genset (minimum)
25038lb
Dry Weight - Genset (maximum)
25677lb
Aingle element canister type air cleaner with service indicator
Air cleaner
Package mounted radiator (except C175)
Emergency stop button
Programmable protective relaying functions:
Over/under voltage (27 / 59)
kVAr (per phase, average & percent)
kVA (per phase, average & percent)
Engine cool-down timer
Generator mounted - rear facing
Overcurrent (50 / 51)
Warning/shutdown with common LED indication of shutdowns for:
Low coolant level
DC volts
Generator phase sequence
Overspeed
Frequency (Hz)
Volts (L-L & L-N)
Reverse reactive power (kVAr) (32RV)
Text alarm/event descriptions
2 Programmable digital outputs
RPM
2 Programmable relay outputs (Form C)
Speed adjust
Alarm acknowledge
kVAr-hr (total)
Digital indication for:
Power factor (per phase & average)
Environmental sealed front face
Controls:
True RMS AC metering, 3 phase, +/-2% accuracy
Low oil pressure
kW (per phase, average & percent)
Engine cycle crank
Accessory module data link
Coolant temperature
Cat ECS 100
24 Volt DC operation
Over/under frequency (81 o/u)
Amps (per phase & average)
4 Programmable relay outputs (Form A)
Reverse power (kW) (32)
Operating hours
Communications
Oil pressure (psi, kPa or bar)
Serial annunciator module data link
kW-hr (total)
6 Programmable digital inputs
High coolant temperature
Failure to start (overcrank)
Low coolant temperature
Lamp test
Emergency stop
Auto/start/stop control
Customer data link (Modbus RTU)
Exhaust flange outlet
Secondary fuel filters
Primary fuel filter with integral water separator
Fuel priming pump
Engine cool-down timer
DC volts
True RMS AC metering, 3-phase, +/-2% accuracy
High coolant temperature
Coolant temperature
Auto/start/stop control
Failure to start (overcrank)
Communications
Oil pressure
Emergency stop
Cat ECS 100
Overspeed
frequency (Hz)
Volts (L-L & L-N)
Engine cycle crank
Warnings/shutdown indicators
Speed adjust
Lamp test
24 Volt DC operation
RPM
4 programmable digital inputs
Low coolant level
Operating hours
Alarm acknowledge
Emergency stop pushbutton
Low oil pressure
Amps (per phase & average)
4 programmable digital outputs
Digital indication for:
IP23 Protection
Matched to the performance and output characteristics of Cat engines
Busbar
Class H temperature rise at 40C ambient
3 phase brushless, Salient pole
6 Lead
Winding temperature detectors
NEMA Class H insulation
Random wound
Internal excitation (IE)
3-phase voltage sensing
Busbar connections
min/max exciter
Caterpillar's digital voltage regulator (CDVR)
RFI suppression
Parts book
Operation & Maintenance Manual
Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
JWAC
Coolant level sensors (Not included with packages without radiator)
Coolant drain line with valve
Radiator fan and fan drive
Fan and belt guards
Dry exhaust manifold
Flanged faced outlet(s)
Fuel priming pump
Secondary fuel filters
Fuel cooler; not included with packages without radiator
Flexible fuel lines - shipped loose
Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
3 Phase voltage sensing
RFI suppression
Class H temperature rise at 40C ambient (125C prime / 150C standby)
Min / max exciter limiter
Exciter diode monitor
Busbar connections, top center mounted, top cable entry
3 Phase brushless, Salient pole
50 Hz models: IEC standard hole pattern
Caterpillar's digital voltage regulator (CDVR) includes:
Random wound
Generator set packages include: Regulator (CDVR)
Reactive droop capability
6 Leads
KVAR / PF modes
NEMA Class H insulation
Winding temperature detectors
Internal excitation (IE)
LV
Woodward 2301A isochronous governor
Lubricating oil
Gear type lube oil pump
Integral lube Oil cooler
Oil filter, filler and dipstick
Fumes disposal
Oil drain lines and valve
Rails - Engine/generator/radiator mounting
Rubber anti-vibration mounts - shipped loose
Battery disconnect switch
Battery and battery rack w/cables
24 Volt electric starting motor
SAE standard rotation
Flywheel and Flywheel housing-SAE No. 00
RH service
Paint - Caterpillar yellow with high gloss black rails & radiator
Air inlet protection
Remote air inlet adaptors
Dual element air cleaners
Exhaust mufflers
Anti-condensation heater
Internal excitation (IE)
Permanent magnet excitation (PMG)
Oversize and premium generators
Cable entry options
2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated Circuit breakers
Busbar connections
Center posts busbars
Controls packaging - Enclosures
2000, 2500, 3200 and 4000 Amp, 3 pole, IEC rated Circuit breakers
Optional busbar power connections
EMAX breakers connections
EMAX Circuit breakers
Breaker harnesses
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Annunciator modules
Customer connection mounting locations
Remote speed adjust
Local PC monitoring
Generator temperature monitoring
Auxiliary boxes
Governors
Customer interface options
EMCP 4.4
Ground (Automatically selected)
Mounting group - External box clips
Vandle proof panel door
Rubber anti-vibration mounts
IBC isolators
Spring type vibration isolators
Oversize batteries
Air starting motor with control and silencer
Jacket water heater
Heavy duty starting system
Charging alternator
Battery chargers
Water level switch gauges
Optional radiator arrangements
Heat exchangers
European Union certification
EU Declaration of Conformity
European Directive genset, DoI (Declaration of Incorporation)
Eurasian Conformity (EAC) mark
Mufflers
Muffler mounting kits
Through-wall installation kit
Flexible fittings
Primary fuel filter
Generator conversion
1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, Form wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, Internal excitation (IE), No. of leads = 6, pitch= 0.6667
Space heater
Pyrometer and thermocouples
Oil level reg-1 shallow pan
Electric prelube pumps
Manual prelube sump pumps
IBC vibration isolators
Spring type vibration isolators
Explosion relief valves
PGS Test report @ 0.80 power factor
Neutral ground-LV
IBC seismic Certifications
PGS Test report @ 1.0 power factor
Neutral grounding connection
Oversize battery set
Jacket water heaters
10 Amp Battery chargers
Ether starting aid
24 Volt dual electric starting motor
20 Amp Battery charger
Engine barring group