3516B Generator Set

Standby Rating2250 kVA
Prime Power Rating2000 kVA
Emissions/Fuel StrategyLow Fuel, Low Emissions
Voltage380 to 11000 Volts
product-tabs-bg

Learn more about our 3516B Generator Set

The 3516B diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. Producing reliable power from 1750 to 2500 kVA at 50 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 % rated load in one step. Our integrated control system keeps you connected through on-site and remote monitoring options. We offer easy-to-use EMCP control panel options, combining your management and diagnostic tools in one. The EMCP 4.4 controller provides multi-generator set paralleling capability, giving you the ability to add generator sets to match your growing power requirements. It's not just quality that matters but customization, choose from a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging to fit unique spatial requirements and environmental conditions. Our 3516B generator sets are developed for such prerequisites, so that you can meet your specific power needs.

Standby Rating
2250 kVA
Prime Power Rating
2000 kVA
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
380 to 11000 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Maximum Rating
2250 kVA
Minimum Rating
1750 kVA
Engine Model
3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69in
Stroke
7.48in
Displacement
69in
Compression Ratio
14.0:1
Aspiration
TA
Fuel System
Electronic unit injection
Governor Type
™3" data-metric=""> Adem3
Length - Minimum
242in
Length - Maximum
242in
Width - Minimum
90in
Width - Maximum
90in
Height - Minimum
98.2in
Height - Maximum
98.2in
Dry Weight - Genset (minimum)
30364lb
Dry Weight - Genset (maximum)
30364lb
Air cleaner; single element canister type
Package mounted radiator
Exhaust flange outlet
Primary fuel filter with integral water separator
Secondary fuel filters
Matched to the performance and output characteristics of Cat engines
IP23 Protection
Busbar
Engine cool-down timer
Frequency (Hz)
DC volts
Volts (L-L & L-N)
Customizable screens
Limiter and exciter diode monitor
Power factor (per phase & average)
1 Programmable relay outputs (Form C
Text alarm/event descriptions
Speed adjust
1 Programmable digital outputs
Overspeed - Emergency stop
4 Programmable relay outputs (Form A)
Emergency stop - Failure to start (overcrank)
Reverse reactive power (kVAr) (32RV)
6 Customer programmable digital inputs
Customer data link (Modbus RTU)
Emergency stop pushbutton
Environmental sealed front face
kW-hr (total) - kVAr-hr (total)
Cat connect
Load histogram feature
RPM - DC volts
Failure to start (overcrank)
Serial annunciator module data link
Coolant temperature
Operating hours
kW (per phase, average & percent)
IVR includes:
Low coolant temperature
Reactive droop capability
Generator set packages include Caterpillar's voltage regulator
Digital indication for:
KVAR/PF modes
Lamp test
Controls:
PLC functionality
0 True RMS AC metering, 3-phase, +/-2% accuracy
Oil pressure (psi, kPa or bar)
Generator mounted - rear facing
Amps (per phase & average)
Low coolant level
3 Analog inputs
Reverse power (kW) (32)
24 Volt DC operation
Over/under voltage (2 7/ 59)
Over/under frequency (81 o/u)
RFI suppression
3 Phase voltage sensing
Cat ECS 100
Alarm acknowledge
Auto/start/stop control
kVA (per phase, average & percent)
Min / max exciter
Engine cycle crank
Low oil pressure
Accessory module data link
High coolant temperature
Warning/shutdown with common LED indication of shutdowns for:
Communications:
Overcurrent (50 / 51)
Number of I/O varies on options selected
Programmable protective relaying functions:
Cat ECS Genset controller
Certified standard PGS provided
Dry exhaust manifold
Flanged faced outlet(s)
Secondary fuel filters
Flexible fuel lines - shipped loose
Fuel cooler; not included with packages without radiator
Fuel priming pump
Paint - Caterpillar yellow except rails and radiators gloss black
Right hand servicing
Flywheel and flywheel housing - SAE No. 00
SAE standard rotation
Caterpillar yellow with high gloss black rails and radiator
Busbar connections, right side extension box, bottom cable entry
3 Phase brushless, Salient pole
Form wound - Permanent magnet excitation (PMG)
Anti-condensation space heater
Busbar connections, top center mounted, top cable entry
6 Leads
Winding temperature detectors
Class H temperature rise at 40C ambient (125C prime / 150C standby)
Form wound
Internal excitation (IE)
NEMA Class H insulation
Low voltage:
Random wound
High voltage:
Medium voltage:
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby
Permanent magnet excitation (PMG)
NEMA standard hole pattern
ADEM A3
Parts book
Fumes disposal
Oil drain lines and valve
Lubricating oil
Integral lube oil cool
Oil filter, filler and dipstick
Gear type lube oil pump
Rails - Engine/generator/radiator mounting
Anti-vibration mounts (shipped loose)
Rubber anti-vibration mounts - shipped loose
Battery and battery rack w/cables
24 Volt electric starting motor
Battery disconnect switch
45 Amp Charging alternator
EMCP 4.4
Exhaust mufflers
Single element filter
Dual element air cleaner
Oversize and premium generators
Permanent magnet excitation (PMG)
Anti-condensation heater
Internal excitation (IE)
Standard ambient radiators
Coolant
Optional installed radiators
Optional installed ATAAC radiators
Standard ambient ATAAC radiators
Water level switch gauges
Circuit breakers, IEC compliant
Circuit breakers, UL listed
Ventilation system
Explosion relief valves
No explosion relief valves
Remote monitoring software
Load share module
Digital I/O module
Generator temperature monitoring & protection
Y Adapters
Elbows
Mufflers
Flange and exhaust expanders
Clean emission parts
Tier 4 dosing cabinet
Exhaust offset
Flexible fittings
Tier 4 clean emission MOD Kits
Flanges
Tier 4 clean emissions module
Primary fuel filter
Fuel priming pumps (Tier 4) - Manual or electric
Air starting motor with control and silencer
Charging alternator
Oversize batteries
Heavy duty starting system
Differential current transformers (DCT)
Thermostat for space heater
Differential current transformers (DCT) 8.7 kV and 15 kV classes
Alternator air cleaner
Generator conversion
Space heater
Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
Pyrometer and thermocouples
Special paint (Colors other than Caterpillar yellow or high performance paints)
US aid emblem
EEC Declaration of Conformity
Automatic transfer switches (ATS)
CSA Certification
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Enclosures: Sound attenuated, weather protective
The following options are based on regional and product configuration:
Integral & sub-base fuel tanks
EU Certificate of Conformance (CE)
Integral & sub-base UL listed dual wall fuel tanks
UL 2200 package
Lube oil in standard sump
Oil level regulator
Prelube pumps
IBC vibration isolators
Spring type vibration isolators
Puck style low efficiency isolators
IBC isolators
Neutral ground connections
Center post busbars
Low voltage Circuit breakers
2700 Frame, four lead, four terminal
Right side power connections
Ground cables between generator and terminal box
Rear power connections
Left side power connections
Standard engine test charge
Torsional vibration analysis reports
PGS Test report @ 1.0 power factor
Fuel consumption test
IBC Certification
Canadian Standards Association certification
PGS Test report @ 0.8 power factor
Generator test report
Generator set fuel consumption test
OSHPD Certification
Air starting motors
Jacket water heaters
Starter cover
10, 20, 35 and 50 Amp Battery chargers
Air pressure regulator
Electric starting motors
Engine barring device
24 Volt battery set - Dry
Platinum, Gold and Silver coverage
TO TOP