D60 GC Generator Set

Exterior View
Interior View

D60 GC Generator Set

Maximum Rating60 ekW
Minimum Rating60 ekW
Emissions/Fuel StrategyU.S. EPA Cert., Tier 3
Voltage208 to 600 Volts
product-tabs-bg

Learn more about our D60 GC Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
60 ekW
Minimum Rating
60 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
269in
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Electronic (adjustable)
Governor Type
™A4" data-metric=""> Mechanical, ADEMA4
Length - Maximum
77.2in
Width - Maximum
43.3in
Height - Maximum
48in
Dry Weight - Genset (maximum)
2054lb
IBC seismic and wind Certifications
Air cleaner
Cartridge type air filter
Breakers (100% UL rated)
3-Pole 100% rated
Second circuit breaker box
Power terminal strip
NFPA battery charger UL10A 120VAC
GCCP 1.2 Control panel
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
WSS1 Low coolant level shut down
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
NFPA110 bundle includes:
WCA1 Low coolant temperature alarm
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
PBC10NU NFPA battery charger
Oil temperature gauge and sender
PAA1 Panel mounted audible alarm
Ground fault relay
Remote E-stop button
Remote annunciator module
Audible alarm
Volt free contacts genset run and common alarm
Discrete I/O module
Overload shutdown via breaker
Low coolant temperature alarm
Protective devices:
Fuel level reading
Low coolant level shutdown
Coolant drain line with valve
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator and cooling fan with guards
Radiator stone guard
12 Leads
Mechanical and electrical governing system - model dependent
Oil drain line with valve
Lubricating oil
Engine and alternator pre-paint, Caterpillar yellow
Batteries
24V battery with rack and cables
IBC seismic and wind Certifications
R Frame auxilliary winding
Cartridge type air filter
NFPA battery charger UL10A 120VAC
Breakers (100% UL rated)
3-Pole 100% rated
Second circuit breaker box
Power terminal strip
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
Ground fault relay
Remote E-stop button
Volt free contacts genset run and common alarm
Oil temperature gauge and sender
Audible alarm
Remote annunciator module
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Discrete I/O module
Radiator transition flange
Sound attenuated enclosure, Level 1
External emergency stop
Sound attenuated Level 2 Enclosure (White)
Panel viewing window
10, 25 and 35 dBA silencer systems
Overhead silencer mounting kit
Emergency vent pipe
Tank riser
5 Gallon spill containment
209 and 394 gallon sub-base fuel tanks
5 Gallon fill containment
Battery heater
Jacket water heater
Coolant heater
Anti-condensation heater
Wiring for canopy space heater
Lube oil sump heater
Permanent magnet excitation (PMG) generator
Cat Alternator
Seismic vibration isolators
4 Hour factory test
Generator test report
PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor