D100 GC Generator Set

Exterior View
Exterior View
Interior View

D100 GC Generator Set

Maximum Rating100 ekW
Minimum Rating100 ekW
Emissions/Fuel StrategyU.S. EPA Cert., Tier 3
Voltage208 to 600 Volts
product-tabs-bg

Learn more about our D100 GC Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
269in³
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
™A4" data-metric=""> Mechanical, ADEMA4
Length - Maximum
82.6in
Width - Maximum
43.3in
Height - Maximum
52.9in
Dry Weight - Genset (maximum)
2222lb
Air cleaner; light duty with disposable element
Air cleaner
Coolant drain line with valve
Radiator and cooling fan with guards
Caterpillar extended life coolant
Fan drive, battery charging alternator drive
GCCP 1.2 Control panel
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Circuit breaker, IEC, 3 pole, mounted in tower panel
IP23 Protection
Tower panel, IP22, bottom cable entry
12 Leads
Voltage regulator (single phase sensing)
Segregated low voltage (AC/DC) wiring panel
Mechanical and electrical governing system - model dependent
Lubricating oil
Oil drain line with valve
Termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Includes lifting provision and drag points
Batteries
24V battery with rack and cables
Engine and alternator pre-paint, Caterpillar yellow
Anti-condensation heater
3 phase sensing
Permanent magnet excitation (PMG)
R Frame auxilliary winding
Quadrature droop kit
Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Coolant heater
Low coolant temperature alarm
Low coolant level shutdown
Earth fault (2 wire only)
Control panel heater
GCCP 1.2 Control panel
Volt free contacts
Emergency stop with key
Voltage adjust potentiometer
Overload shutdown via breaker
Panel mounted audible alarm
Battery charger
Earth leakage (2 wire only)
Speed adjust potentiometer
Sound attenuated Level 2 enclosure
Low fuel level alarm
Bunded fuel tank
Low fuel level shutdown
High fuel level alarm
Battery removal
Electronic governor
Industrial silencer
External single point lift - enclosure
Silencer installation kit
PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor
Packing case - canopied set
Packing case - compact set
Stone guards/rad trans flange
TO TOP