C4.4 Generator Set

Exterior View
Exterior View

C4.4 Generator Set

Maximum Rating100 ekW
Minimum Rating72 ekW
Emissions/Fuel StrategyU.S. EPA Cert., Tier 3
Voltage110 to 480 Volts
product-tabs-bg

Learn more about our C4.4 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
100 ekW
Minimum Rating
72 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
110 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
Engine Model
® C4.4" data-metric=""> Cat® C4.4
Bore
4.1in
Stroke
5in
Displacement
268.5in³
Compression Ratio
16.2:1, 17.25:1, 18.2:1 or 18.3:1
Aspiration
Turbocharged
Fuel System
Direct Injection or Common Rail
Governor Type
Mechanical
Length - Maximum
75.8in
Width - Maximum
44.1in
Height - Maximum
53.6in
Air cleaner; light duty with disposable element
Radiator and cooling fan with guards
Coolant drain line with valve
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
GCCP 1.3
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
Voltage regulator (single phase sensing)
12 Leads
IP23 Protection
Circuit breaker, IEC, 3 pole, mounted in tower panel
Segregated low voltage (AC/DC) wiring panel
Tower panel, IP22, bottom cable entry
Mechanical and electrical governing system - model dependent
Oil drain line with valve
Lubricating oil
Termination points for coolant and lube oil drain lines
Includes lifting provision and drag points
Captive linear vibration isolators between base and engine-generator
24V battery with rack and cables
Batteries
Engine and alternator pre-paint, Caterpillar yellow
Permanent magnet excitation (PMG)
R Frame auxilliary winding
Anti-condensation heater
R Frame auxilliary winding
Quadrature droop kit
LC Frame alternator with coastal insulation protection
3 phase sensing
Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Low coolant level shutdown
Coolant heater
Low coolant temperature alarm
GCCP 1.3
Control panel heater
Earth leakage (2 wire only)
Panel mounted audible alarm
Volt free contacts
Emergency stop with key
Battery charger
Overload shutdown via breaker
Speed adjust potentiometer
Voltage adjust potentiometer
Sound attenuated Level 2 enclosure
Sound attenuated Level 1 (galv)
Rental pack - CAE rental option only
Upgrade to STD set for CE
Skidbase for CALG enclosure sets
Low fuel level alarm
Open set narrow tankbase
Low fuel level shutdown
Compact skidbase for open set
High fuel level alarm
Bunded fuel tank
Certification for CIS
Electronic governor
Industrial silencer
External single point lift - enclosure
Battery removal
Silencer installation kit
PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor
Packing case - compact set
Packing case - canopied set
Stone guards/rad trans flange
TO TOP