3516C Tier 4 Final

Exterior View

3516C Tier 4 Final

Standby Rating2500/2000 ekW
Prime Power Rating1825/2250 ekW
Emissions/Fuel StrategyU.S. EPA Certified
Voltage480 to 13800 Volts
product-tabs-bg

Learn more about our 3516C Tier 4 Final

The 3516C HD generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The engines are certified to the US EPA Tier 4 Final emissions levels. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

Standby Rating
2500/2000 ekW
Prime Power Rating
1825/2250 ekW
Emissions/Fuel Strategy
U.S. EPA Certified
Voltage
480 to 13800 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Mission Critical, Prime
Maximum Rating
2500 ekW
Minimum Rating
1825 ekW
Engine Model
3516C HD, ATAAC, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69in
Stroke
8.46in
Displacement
78in
Compression Ratio
14.7:1
Aspiration
TA
Fuel System
Electronic unit injection
Governor Type
â„¢A4" data-metric=""> ADEMâ„¢A4
Length - Minimum
275.4in
Length - Maximum
285.5in
Width - Minimum
93.7in
Width - Maximum
101.2in
Height - Minimum
116.9in
Height - Maximum
118.7in
Dry Weight - Genset (minimum)
37200lb
Dry Weight - Genset (maximum)
40280lb
Single element with service indicator
Heavy duty electric starter(s)
Standard Ambient Radiator
Rails
Cat ECS 100
Ethernet
Random wound
Internal Excitation (IE)
Busbar
Standard batteries
Oversized batteries
Battery charger - 10A
Battery charger - 20A
Battery charger - 40A
Air starter(s)
Jacket water heater
High Ambient Radiator
Critical grade (25 dB)
Rubber
Spring vibration Isolators
Seismic rated vibration isolators
Cat ECS 200
EMCP 4.4
Local annunciator module
Remote annuciator module
Expansion I/O module
Remote monitoring software
Cellular
2 year (Prime)
3 year
5 year
10 year
Silver
Gold
Platinum
Platinum plus
Form wound
Permanent Magnet (PM) Excitation
80°C
105°C
125°C/130°C
150°C
480V
600V
4160V
6300V
6600V
6900V
12470V
13200V
13800V
Anti-condensation space heater
Stator and bearing temperature monitoring and protection
Circuit breaker
1600A
2000A
2500A
3000A
3200A
4000A
5000A
Electrically operated
LSI
LSI-G
LSI-P
LSIG-P
Automatic transfer switch (ATS)
Paralleling switchgear
Paralleling controls
UL 2200
IBC seismic certification
HCAI/OSHPD OSP preapproved
TO TOP