3412C | 800 kVA 50Hz Generator Set

Exterior View

3412C | 800 kVA 50Hz Generator Set

Maximum Rating800 kVA
Minimum Rating725 kVA
Emissions/Fuel StrategyLow Fuel Consumption
Voltage380 to 415 Volts
product-tabs-bg

Learn more about our 3412C | 800 kVA 50Hz Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
800 kVA
Minimum Rating
725 kVA
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime
Engine Model
3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
5.4in
Stroke
6in
Displacement
1648.86in³
Compression Ratio
13:01
Aspiration
Turbocharged, Air to Air Aftercooled
Fuel System
Pump and Lines
Governor Type
™ A5" data-metric=""> ADEM A5
Length - Maximum
162.4in
Width - Minimum
75in
Width - Maximum
78.3in
Height - Maximum
75in
Dry Weight - Genset (minimum)
12039lb
Dry Weight - Genset (maximum)
13030lb
Air cleaner, single element canister type with service indicator
GCCP Control panel
DC volts
Environmental sealed front face
kVA (per phase, average & percent)
Voltage adjust
Compatible with the following optional modules:
Low coolant level
RPM
Engine cycle crank
Over/under frequency (81 o/u)
Programmable protective relaying functions:
kVAr (per phase, average & percent)
coolant temperature
Local annunciator
Reverse reactive power (kVAr) (32RV)
2 Programmable digital outputs
Emergency stop
Amps (per phase & average)
Volts (L-L & L-N)
Failure to start (overcrank)
Speed adjust
24 Volt DC operation
Remote Serial annunciator
kW (per phase, average & percent)
Low coolant temperature
High coolant temperature
Over/under voltage (27 / 59)
Reverse power (kW) (32)
Run/auto/ stop/control
Operating hours
Customer data link (Modbus RTU)
Power factor (per phase & average)
Generator temperature monitoring module
6 programmable digital inputs
Overspeed
Text alarm/event descriptions
4 programmable relay outputs (Form A)
kW-hr (total)
Features include:
Remote CAN annunciator
Digital I/O module
Generator phase sequence
Low oil pressure
Warning/shutdown with common LED indication of shutdowns for:
Accessory module data link
Emergency stop pushbutton
Serial annunciator module data link
Frequency (Hz)
2 Programmable relay outputs (Form C)
Oil pressure (psi, kPa or bar)
Digital indication for:
Communications
Overcurrent (50 / 51)
Caterpillar extended life coolant
Coolant level shutdown
Radiator with guard (Sized for 50 degrees C)
Fan and belt guards
Coolant drain line with valve, piped to edge of base
Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
Water seperator
Flexible fuel lines terminated on base
Primary and Secondary fuel filters
Fuel priming pump
Class H insulation
2:1 Volts/Hz
3-phase sensing
Class F temperature rise
12 Leads
VR6 voltage regulator
Busbar termination
Reactive droop
SR4B self excited
Cat electronic governor
Lubricating oil
Oil drain line with valve, piped to edge of base
Fumes disposal, piped to front of radiator
Oil filter
Base, formed steel with linear vibration isolators between base and engine-generator
45 amp Charging alternator
Fuel shutoff solenoid
Battery with rack, cables
24 volt starting motor
Heavy duty air cleaners
Open element air cleaners
Dual element air cleaners
1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
GCCP Control panel
Vandal proof panel door
Remote custom annunicator
Ground fault relay
Common alarm/shutdown relay
Generator running VFC
GCCP Control panel
Local discrete I/O package
First local annunicators
Generator temperature monitoring package
Jacket water heaters
Radiator duct flange
Eurasian Conformity (EAC) mark
Through wall installation kit
Manifold and turbocharger guards
Elbow kit
Mufflers
Digital voltage regulator
Oversize and premium generators
Permanent magnet excitation (PMG)
Space heater
Manual sump pump
Fuel tank base (1200 ltr)
PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor
Battery disconnect switch
Oversize batteries
Battery chargers
Heavy duty starting system
Electronic load share
TO TOP